Test operation
Same switch as used in Emergency operation.
Test operation is needed in special occasion when you need to test the “cooling operation” even with
the room temperature below 16°C, therefore it is not for the normal operation at all.
Press the Emergency operation switch and hear the beep once, then keep on pressing the switch for
more than 5 seconds but no more than 10 seconds. After the first 5 seconds you will hear two beeps
then release the switch and you will have the Test Operation Mode.
The Test Operation Mode will run the air conditioner at “cooling” with air flow speed at “Hi” for 30
minutes and stops automatically.
Termination of emergency or test operation
You can terminate the operation when you hear a beep by either pressing the switch once more, or by
operating through remote control.
When you operate through remote control, is automatically get back to just normal operation mode by
remote control.
E AIR FILTER
This air conditioner is equipped with a 3 in 1 filter to clean the circulated room air.
a. Anti-Dust: Screening dust and large particles in the air.
b. Anti-Odor: Deodorizing bad smells from cigarette (acetaldehyde), pets (ammonia), and garbage.
c. Anti-Germ: Preventing E-coli, MRSA, and other bacteria from proliferating.
F CLEANING
Cleaning the front panel
1. Switch the machine off and remove the plug from the socket.
2.
Hold the front panel at position “a” and pull it upwards.
3. Clean with a soft dry cloth. Use lukewarm water (max. 30° C) to remove stub-
born dirt.
4.
Never use volatile substances, such as benzine, gasoline, thinner or abrasives
to remove dirt.
5. Never spray water on or in the indoor unit. Danger!
6.
Replace the fr
ont panel and close it by pushing position “b” down.
G
NOTE
The 3 in 1 air filter is delivered in a plastic packaging. Remove plastic bag and install the filter.
This filter takes away unhealthy particles out of the room environment.
G
N
OTE
Emergency operation at the temperature between above 23°C and below 26°C just switch the
machine in operation in “cooling mode” without actually “cooling”. It is not possible to operate